Release of selmo Studio Features Version 2023.7 SP1!
It contains a number of optimizations and new features.
Here you can find the list of key features of the new version 2023.7 SP1:
- Selmo Studio: Project memory layout optimization added. This will reorganize all selmo basic zone bit and operand arrays at PLC level.
- Selmo Studio: Error after pressing button "Read request ID and status" on LicenseView
- Selmo Studio Assembly Layer: Problem with Selmo Motion driver
- Selmo Studio System Layer: Icon at InOut and Out Zone in System Layer when keep alive is active
- Selmo Studio Assembly Layer: Add "KeepAlive" attribute to driver in out definitions
- Selmo Studio System Layer: Icon at InOut Zone in System Layer when keep alive is active
- Selmo Studio: Changed "Upload" and "Download" notations which was used with PLC communications
- Selmo Studio: New property "show indication" at step level to show the warning symbol at sequence and hardware zoner level on the HMI, e.g. a manual action is necessary
- Selmo Studio: fixed zone fast rename with mem zones not working
- Selmo Studio: fixed analog output value not working in manual mode
- Selmo Studio Logic Layer: fixed jump to a jump or decision connection is not possible
- Selmo Studio System Layer: Separate output state of set and reset mem zones while online
- Selmo Studio: fixed bug where the decision system zone input and outputs are not renamed correctly
- Selmo Studio System Layer: Fixed clone to inverted not cloning analog function
- Selmo Studio: Fixed Multi-Master not working
- Selmo Studio: Fixed unchangeable Web View Address
- Selmo Studio: Added property "Output Distribution" to InOut- and Out-Zones. Here you can set a parameter where the output value of the zone will be distributed respectively copied.
- Selmo HMI: Fixed bug where the feedback is not displayed in manual button when zone input mode is set to analog
- Selmo HMI: Fixed bug where no variables can be added to var out scope feature
- Selmo HMI: Prioritize error before warning in alarm line
- Selmo HMI: Add lamp test buttons
- Selmo HMI: HWZ buttons alignment fixed
- Selmo HMI: Sequence lamp refactored
- Selmo HMI: HwZone lamp added
- Selmo HMI: Sequence View manual functions and parameter at the same time
- Selmo HMI: monitoring entries overloads alarm history
- Selmo HMI: System Error, AdsException when using monitoring check feature
- Selmo HMI: Exception after pressing time monitoring button
- Selmo HMI: Step Time Monitoring ADS fixed
- Selmo HMI: Add sequence interlock message to alarm line
- Selmo Studio: Added Zone Input Mode "ParameterInput" to enable possibility to compare two parameters as feedback
- Selmo Studio: Added "Window" as analog function to Zones and CMZ with possibility to define the positive and negative threshold with parameters
- Selmo Standard: Added feature "Ghost Mode" to simulate feedback signals with a separate delay and its own operating mode
- Selmo Standard: Added possibility to CMZ to add parameters as compare to input of CMZ
- Selmo Studio: Now it is possible to activate full license without internet connection
- Selmo HMI: Fixed bug where OPC UA alarms are shown with UTC time
- Selmo Standard: Global and hardware zone TCMZ have now the same functionality as sequence CMZ like auto reset and delay.
- Selmo HMI: Ghost mode is now only activatable when hardware zone is in manual mode and the safety function key is selected.
- Selmo Studio System Layer: With the feature "Auto fill operands" you can completing operands of new steps with the values of the contiguous steps.
- PLC code generation: signal any sequences in time out
- PLC code generation: signal any sequence end of cycle reached
- PLC code generation: any sequence in single step bit
The package is delivered via auto-updater.